- Advanced refrigeration technology, microprocessor controls and high-quality construction
- Safeguard valuable research with freezers that offer superior reliability and performance
- Suited for laboratories that require sophisticated electronic monitors and alarms for the highest level of sample protection.
- Programmable microprocessor control
- Patented refrigeration system
- State-of-the-art electronics ensure the highest level of sample protection.
- Units offer up to 20% more heat removal capacity, 15% less power consumption and 15% less heat emission than comparable ultra-low temperature freezers.
- Precise temperature control from -50° to -86°C, adjustable in 1°C increments
- Door-mounted, eye-level control panel with easy-to-read LED display and touchpad data entry
Part Number |
Description |
ULT1786-10-A |
17.4 cu. ft.; 115V 60Hz, 16A |
ULT1786-10-D |
17.4 cu. ft.; 208/230V 60Hz, 16A |
ULT2186-10-A |
20.4 cu. ft.; 115V 60Hz, 16A |
ULT2186-10-D |
20.4 cu. ft.; 208/230V 60Hz, 12A |
ULT2586-10-A |
24.8 cu. ft.; 115V 60Hz, 16A |
ULT2586-10-D |
24.8 cu. ft.; 208/230V 60Hz, 12A |
Monitoring and Alarm Systems
- On-board diagnostics continuously monitor sensors to ensure proper performance
- Control Setpoint sets cabinet temperature, Cabinet Temperature displays the temperature
- Automatic Incident Monitor (AIM) identifies temperature deviation due to power or temperature failure
- Time Delay feature delays restart after power failure
- Voltage Buck/Boost corrects line voltage into the unit
- Low Voltage Surge Protection minimizes voltage spikes
- Life-Guard Alert monitors compressor performance, automatically adjusts to internal and external conditions
- Clean Filter, Alarm Battery Low, and Voltage indicators
- Battery backup supplies control panel in case of power failure
- Key-operated main power and alarm switch locks temperature and alarm setpoints
- Audible/visual power and temperature failure alarms automatically activate during a temperature deviation
- Extreme Ambient Alert warns if room temperature may affect performance
- Alarm Test simulates temperature alarm condition
- Alarm Reset mutes audible alarm and resets AIM
- Remote alarm contacts for external alarm/monitoring system
Construction
- High-strength steel cabinet with corrosion-resistant coating
- Minimum 5 in. (12.7cm) CFC-free, foamed-in-place urethane insulation (outer door: minimum 3.5 in. [89mm])
- Integrated door handle for one-handed operation
- Built-in key lock (padlock compatible)
- Outer door gasket seals with five points of sealing contact
- Inner doors made of high-impact ABS plastic with recessed handles
- Stainless-steel interior shelves
- Patented Refrigeration System features CFC-free DuPont* Suva* 95 in low stage
- 1hp Industrial-grade compressors
- Downfeed evaporator
- Washable condenser filter
- 1 in. (2.5cm) dia. access ports
- RS-232 data port
- Heavy-duty 2 in. (5cm) locking, tandem wheel casters
Certifications: Meet NEMA, UL61010-1, UL471, CUL, CE, TUV, IEC60335-2-89/Climate Class T (Tropical) requirements
Accessory racks, cryoboxes, microplates, and bulk storage components—completely interchangeable with all Revco PLUS -86°C freezers—are available separately. Optional built-in Temperature Chart Recorder (7-day, 6 in. dia.) and LN2/CO2 backup systems must be specified at time of order. Freestanding LN2/CO2 Backup System also available. Contact your Customer Service Representative for more information.
|