Amerex Model HVA-85 autoclave. 85L; 105° to 135°C operating range; floor model; programmable steam exhaust rate; agar sterilization and melting modes; digital display; microprocessor control; sterilization timer: 1-250 min; requires but does not include a

ERP
AMX-AT-HVA-85
The Largest 100% Canadian Owned and Operated Lab Equipment Distributor and Service Provider.
Free Technical Support
In-depth and personal over-the-phone support at no cost.
Quality Parts & Accessories
Mandel uses manufacturer-specified parts for all repairs and maintenance.
Details
Portable top-loading autoclaves with cooling fan and advanced safety and user-friendly features.
Features
- Space-saving design with lid opening upward
- Standard built-in cooling fan for faster post- sterilization cooling
- Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C
- Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying
- One-touch lever to easily open and close chamber lid
- Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up
- Door-closure sensor prevents a cycle from starting unless the door is closed properly
- In-process display shows the status and the progress of sterilization cycle
Specifications
| MODEL |
HVA-85
|
HVA-110
|
| TEMPERATURE | ||
| Operating Range |
105ºC to 135ºC
|
|
| Display Range |
137ºC
|
|
| Agar Warming Range |
After sterilization, agar can be maintained from 45ºC to 60ºC
(programmable) to prevent coagulation for up to 20 hours. |
|
| GAUGE PRESSURE | ||
| Maximum Allowable |
38 psi (0.26MPa)
|
|
| Operating Range |
3 to 30 psi (0.021 to 0.206MPa)
|
|
| TIMER | ||
| Sterilization |
1 to 250 minutes
|
|
| DIMENSIONS | ||
| Overall (W x D x H) |
26.0"" x 25.6" x 39.4"
(66 cm x 65 cm x 100 cm) |
26.0" x 25.6" x 46.4" in
(66 cm x 65 cm x 118cm) |
| Chamber (Diameter x Height) |
85 litres
16.5" x 24.2" (42.0 cm x 61.5 cm) |
110 litres
16.5" x 31.3" (42.0 cm x 79.5 cm) |
| SAFETY DEVICES |
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
|
|
| PROGRAMS | ||
| 1. For agar |
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion
|
|
| 2. For liquids |
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion
|
|
| 3. For solids |
Heating -> Sterilization -> Auto exhaust (fast) -> Completion
|
|
| ACCESSORIES | ||
| Stainless steel |
Mesh wire baskets, buckets (pails), and round test tube racks
|
|
| Factory or field installed |
Data logger
|
|
| POWER | ||
| Source |
208V / 220V / 240V, 50 / 60 Hz, single phase
|
|
| Consumption |
3000 watts (3000VA)
|
4000 watts (4000VA)
|
| SHIPPING WEIGHT |
282 lb (128 kg)
|
308 lb (140 kg)
|
WARRANTY: Autoclaves are protected by a 12-month warranty.
Only registered users can write questions. Please Sign in or Create an account
Recently Viewed
-
Amerex Model HVA-110 autoclave. 110L; 105° to 135°C operating range; floor model; delayed auto-start; auto steam exhaust; agar sterilization; digital display; microprocessor control; sterilization timer: 1-250 min; requires but does not include a basket iRegular Price CA$37,219.00 Special Price CA$33,497.10 -
Lucigen MPC Protein Precipitation Solution, 500mL, +22°C.Regular Price CA$2,878.00 Special Price CA$2,446.30 -
Lucigen MasterPure™ Yeast RNA Purification Kit 100 Purifications.Regular Price CA$1,170.00 Special Price CA$994.50
Quick Order
Need a quote for our lab instruments or supplies?
GET IN TOUCH WITH US TODAY!
Quick Order