Experience highly sensitive measurement and stable analysis throughout the entire wavelength range with the high-performance SPD-40V UV-Vis detector. Noise and drift are minimized by the fully temperature controlled optical system and flow cell. The signal-to-noise ratio is enhanced by an improved optical system and a high-order digital filter. It can be operated in dual wavelength mode that simultaneously provides chromatograms of two wavelengths or ratio chromatograms, and in wavelength scanning mode to provide absorbance spectra of a single peak. The built-in cell ID stores the cell information in the LabSolutions method. Both the deuterium (D2) and tungsten (W) lamps have a built-in chip to monitor usage hours.

SPD-40V UV-Vis Specifications

  • Extended wavelength range of 190 nm - 1000 nm, with wavelength accuracy ± 1 nm
  • Low noise (4.0 x 10-6 AU), and drift (0.1 x10-3 AU/hour) for maximum sensitivity
  • Contains both a deuterium (D2) and tungsten (W) lamp
  • Built-in holmium filter for wavelength accuracy check
  • Users can monitor two wavelengths simultaneously with a sampling period of 0.5 seconds
  • Monitored and controlled through a standard web browser or various HPLC and LC-MS/MS software
  • Built-in cell ID that is automatically recorded in analysis data file
  • Linear up to 2.5 AU (ASTM method)
  • Pressure tolerance of 12 MPa
  • Standard flow cell has a 10 mm path length, 12 µL volume; maximum pressure MPa/120 bar
  • Integrated 2 channel analogue output for triggering a fraction collector
  • Optional flow cells that can be changed by the user: UHPLC (8 µL), semi-micro (2.5 µL), inert (12 µL), preparative (0.8 µL, 1.6 µL, or 4.0 µL depending on path length) and high-pressure (12 µL)

Nexera HPLC/UHPLC UV-Vis Detector - SPD-40

SPD-40 UV-vis Detector for HPLC and UHPLC

The SPD-40 is a cost-effective UV-Vis detector with a deuterium (D2) lamp and fully temperature-controlled optics for an exceptional level of sensitivity and baseline stability. A variety of flow cells that can be replaced easily by the user are avaialble for applications ranging from UHPLC, semi-micro, and preparative.

SPD-40 UV-Vis Specifications

  • Wavelength range of 190 nm - 700 nm with an accuracy of ± 1 nm
  • Low noise (4.0 x 10-6 AU) and drift (0.1 x 10-3 AU/hour) for unparalleled sensitivity
  • Fully temperature-controlled optics (optical bench, lamp housing, and flow cell) for reliable operation even when the room temperature changes
  • Users can monitor two wavelengths simultaneously with a sampling period of 0.5 seconds
  • Monitored and controlled through a web browser and various HPLC and LC-MS/MS software
  • Built-in cell ID that is automatically recorded in analysis data file
  • Linear up to 2.5 AU (ASTM method)
  • Standard flow cell has a 10 mm path length, 12 µL volume maximum pressure 12 MPa/120 bar
  • Automatic wavelength accuracy check and correction
  • Integrated 2 channel analogue output for triggering a fraction collector
  • Optional flow cells that can be changed by the user: UHPLC (8 µL), semi-micro (2.5 µL), inert (12 µL), preparative (0.8 µL, 1.6 µL, or 4.0 µL depending on path length), and high-pressure (12 µL)

Nexera HPLC/UHPLC Photodiode Array Detector - SPD-M40

SPD-M40 Photodiode Array Detectors for UHPLC and UHPLC

Boost your high sensitivity measurements over a wide wavelength range. The SPD-M40 has great accuracy in identification of compounds from absorbance spectra and performs an impurity check on all peaks. The industry leading i-PDeA deconvolution algorithm spectrally resolves coeluting peaks. The optical system guarantees both a wide linearity range and a superb signal-to-noise ratio performance at the same time. It has improved stability in analysis through flow cell/polychromator/lamp compartment temperature control. Each SPD-M40 is equipped with a UV cutoff filter, which allows even less variation and more robust analysis by minimizing sample decomposition.

SPD-M40 Specifications

  • Wavelength range of 190 nm - 800 nm, wavelength accuracy ± 1 nm, noise level of 4.5 x 10-6 AU, and drift less than 0.4 x 10-3 AU/hour
  • Contains both a deuterium (D2) and tungsten (W) lamp
  • UV cut-off filter that removes wavelengths below 240 nm from entering the flow cell
  • Has a 1024 element diode array. Fully temperature-controlled optics, including the optical bench, lamp housing, and flow cell. Monitored and controlled with a standard web browser
  • Built-in Cell ID that is automatically recorded in analysis data
  • Linear up to 2.5 AU (ASTM method). Pressure tolerance of 12 MPa
  • Automatic wavelength accuracy check and wavelength correction
  • Integrated 4 channel analogue output
  • Optional flow cells that can be changed by the user: UHPLC, semi-micro, inert, preparative and high-pressure cell
  • Capable of using the i-PDeA II deconvolution algorithm to resolve co-eluting peaks

Nexera HPLC/UHPLC Photodiode Array Detector - SPD-M30A

SPD-M30A Photodiode Array Detectors for HPLC and UHPLC Shimadzu offers the flexible photodiode array detector, SPD-M30A with minimal dispersion for fast UHPLC separations, ideal for USP compliant analogue tests. It has improved accuracy in compound identification from absorbance spectra, and can perform an impurity check for all peaks. It leads the industry in deconvolution algorithms to resolve coeluting peaks. Low dispersion capillary cells and multi-wavelength settings guarantee high sensitivity analysis of trace components. The capillary cell and optical system improve signal level and reduced noise level. Stray light compensation technology and temperature control features enable precise identification, quantification, and peak purity analysis at trace levels. Utmost flexibility is guaranteed for high-speed multi-wavelength (up to 4 discrete channels) sampling range. Up to four wavelengths can be output, allowing the SPD-M30A to perform as a multi wavelength UV detector.

SPD-M30A Specifications

  • 1024 element diode array with resolution of 0.5nm/element and < 1.4 nm spectral resolution
  • Wavelength range of 190 to 700 nm with a wavelength accuracy of ±1 nm is achieved through a Deuterium (D2) lamp
  • Baseline drift less than 0.5 x 10-3 AU/h (under specified conditions) and noise level of less than 0.4 x 10-6 AU (under specific conditions)
  • Standard flow cell has an optical path length of 10mm and 1µL volume; maximum pressure 8 MPa/80 bar
  • Optional high-sensitivity cell with an optical path length of 85mm and capacity of 9µL can be installed
  • 4-channel analogue output to trigger a fraction collector
  • Monitored and controlled through a web browser and various HPLC and LC-MS/MS software

Nexera HPLC/UHPLC Fluorescence Detector - RF-20A/RF-20Axs

RF-20A and RF-20Axs Fluorescence Detectors for HPLC and UHPLC Experience exquisite sensitivity with RF-20A and RF-20Axs fluorescence detectors for HPLC and UHPLC separations. Built with maintenance in mind, both the cell and lamp replacement are accessed through the front panel - no additional position adjustment is required. Monitor two EX and EM wavelength pairs simultaneously, or up to four pairs with LabSolutions software control. The RF-20xs has superior S/N performance due to its temerature controlled flow cell.

RF-20A and RF-20Axs Specifications

  • RF-20A has a wavelength range of 200 to 650 nm
  • RF-20AXS has a wavelength range of 200 to 750nm
  • Optional PMT or Photo-multiplier (both) to extend to 900nm
  • Both detectors have wavelength accuracy of ±2 nm and precision of ±0.2nm
  • Superior with signal-to-noise ratio of at least 1200 for RF-20A and 2000 for RF-20Axs, allowing ultrafast analysis of trace-level analytes
  • Standard cell with a 12uL volume, or, a semi-micro cell with 3uL volume are available
  • Operating temperature 4 to 35°C

Nexera HPLC/UHPLC Refractive Index Detector - RID-20A

RID-20A Refractive Index Detector for HPLC and UHPLCShimadzu offers a cost-effective, high performance, easy-to-use refractive index detector with excellent stability. The RID-20A is equipped with a dual temperature control structure for the optical system and flow cell. Modified thermal design provides excellent baseline stability and shorter initial stabilization time.

RID-20A Specifications

  • Measurement range 1 to 1.75 RIU
  • Noise ≤ 2.5 x 10-9 RIU and Drift ≤ 1 x 10-7 RIU/h
  • Range modes are A-mode (0.01 x 10-6 to 500 x 10-6 RIU); P- and L-mode (both at 1 x 10-6 to 5000 x 10-6 RIU)
  • Ideal maximum flow rate of 20 mL/min (150 mL/min in option)
  • Cell volume 9µL and cell’s maximum pressure 2 MPa
  • Operating temperature range 4 to 35°C, with cell temperature controls between 30 and 60°C
  • Equipped with polarity change

Nexera HPLC/UHPLC Conductivity Detector - CDD-10AVP

CDD-10AVP Conductivity Detector for HPLC and UHPLCExperience reliable, user-friendly, versatile, and high sensitivity ion chromatography (IC) detection for environmental, water testing, and food laboratories. With its wide dynamic rage, the CDD-10AVP conductivity detector assures minimal noise and drift. This versatile high sensitivity conductivity detector is intended for a non-suppressed system.

CDD-10AVP Specifications

  • The CDD-10AVP has a small cell volume of 0.25µL
  • Low noise (< 4 nS/cm) and low drift (< 25 nS/cm/h) for high sensitivity analysis
  • Maximum cell pressure of 2.9MPa (29 bar)
  • Wide operating temperature range (4 to 35°C) and cell temperature control range from 25 to 55°C
  • Time constant settings from 0.05 to 10 seconds
  • In-run autozero and correction of baseline shifting is possible