LCMS-8060NX (LC-MS/MS)

Shimadzu's most powerful tandem mass spectrometer, the LCMS-8060NX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity. Incorporation of a new IonFocus electrospray unit and newly designed ion guides deliver robust operation through reduced matrix effects and less contamination inside the instrument, resulting in maximized uptime, the utmost in data quality, and a more efficient analytical workflow.


The Culmination of Shimadzu's Expertise in Triple Quadrupole Mass Spectrometry

IonFocus™ ESI Probe

In the new IonFocus system, ions are propelled into the LCMS-8060NX with the greatest efficiency while neutral particles are expelled to reduce noise and provide the highest stability.  A new heat assist design increases desolvation efficiency and promotes superior ionization of a wide range of compounds (patented technology).

UF-Qarray™Ⅱ, UF-Lens™Ⅱ

Newly designed ion guides and optimized voltages achieve more robust operation and fewer maintenance cycles for higher laboratory throughput.

Easy Maintenance Interface

Shimadzu engineering means attention to detail. Consumable parts like the ESI spray needle and the inlet desolvation line (DL) can be changed quickly and easily without breaking vacuum. Ion optics in the vacuum chamber can be removed simply and without tools for easy cleaning.

 

Replacement of the Desolvation Line

Steps to replace the DL

 

Replacement of the ESI Capillary

 Steps to replace the ESI capilliary


Robustness and Ease of Use

Maximized Sensitivity, Minimized Matrix Effects

Shimadzu's new IonFocus system propels analyte ions towards the MS inlet while ejecting neutrals which contribute to matrix effects. Using the LCMS-8060NX's world-leading polarity switching speed and data acquisition rate, residual pesticides and herbicides were analyzed in tea leaves. The chromatograms below show the data enhancement obtained as the IonFocus lenses introduce ions into the mass spectrometer more efficiently, improving the signal intensity. Of the 100 compounds tested, 96% showed excellent recoveries.

Robust Performance for Higher Throughput 

The LCMS-8060NX employs new ion guides, the UF-Qarray II and the UF-Lens II, to increase robustness while maintaining high ion transmission efficiency. Improved robustness means higher laboratory throughput as maintenance interval times increase.
The urine metabolite data shown below provides confidence for the analysis of biological matrices. After the analysis of 1000 urine samples, prepared only by dilution with water, the LCMS-8060NX delivers superior data stability without loss of sensitivity.
 

Intelligent Operational Parameters 

Designed for easy operation, the LCMS-8060NX incorporates optimized parameters based on AI research that enable high sensitivity without manual optimization. Out-of-the-box LCMS-8060NX performance has been improved an average of 2.6 times for a variety of analytes, making the job of method development that much easier.

Efficient Desolvation for High Efficiency

A new heat-assisted design improves the desolvation efficiency and dramatically enhances the sensitivity for challenging molecules such as steroid hormones.


Intelligent Automation Improves Workflow Efficiency

Intelligent Start-up with Smart Flow Control

HPLC columns can be damaged by sudden pump starts and stops or extreme gradient changes. The new Nexera automatically uses FlowPilot (Smart Flow Control) to increase the flow rate gradually to the set point. There is no need to create startup protocols for each analysis.

Streamlined Data Review

Configurable displays for multiple chromatograms, colour-coded flags to highlight results that are out of range, and standard report templates all enable the laboratory technician to process samples quickly and correctly.

Automatic Optimization of MS Conditions

Simply set the sample in place and enter the sample information, and MRM and interface parameter optimization will be carried out automatically. The optimization results are shown graphically, reducing the time and effort needed for evaluation.

LC/MS/MS Method Packages and MRM Libraries

Several method packages are available for quick method startup. Analysis can begin right away without MRM optimization or tedious method development.

Advanced Autosampler Functions 

The SIL-40 autosampler has programable micro-volume liquid handling capabilities.  Apply these sample pretreatment parameters from a simple graphic interface, reducing labor and increasing precision in derivatization, co-injection, etc.

Automatic co-injection with water matches mobile phase conditions, preserving peak shape for early eluters


Software Solutions for Acquisition to Data Review

LabSolutions Connect™ and LabSolutions Insight™ provide support for the entire analytical workflow, from optimization of MS conditions to data processing, for maximum efficiency.

LabSolutions Connect

Automatically stay organized with LabSolutions Connect’s file management system. File locations are automatically determined by file type, enabling the technician to carry out analysis or data processing without having to remember file paths. In addition, LabSolutions Connect makes comprehensive MS optimization possible. MRM parameters, such as precursor ion selection, collision energy voltage, and product ion selection, are automated, and Connect software performs intelligent, stepwise optimization of the interface voltage, gas flows, and source temperatures.

High throughput data analysis software package that enables faster quantitative analysis and more effective reviewing of multi-analyte panels particularly for food, cannabis, clinical research, and forensics markets.