Standard Solid Door Pharmacy Refrigerator 36 Cu. Ft. 36°F to 46°F (2°C to 8°C). 110 - 120V AC, 15A breaker, NEMA 5-15 receptacle. Two (2) year parts and labor warranty, Five (5) years compressor warranty.
The Largest 100% Canadian Owned and Operated Lab Equipment Distributor and Service Provider.
Free Technical Support
In-depth and personal over-the-phone support at no cost.
Quality Parts & Accessories
Mandel uses manufacturer-specified parts for all repairs and maintenance.
Details
These pharmacy refrigerators are designed for reliable and cost-effective cold storage.
This model features low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including keyed door locks and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, and adjustable inner shelving to optimize your workflow.
All features are designed to heighten performance and efficiency in your clinical setting.
Specifications
| Storage capacity (Cu. Ft.) | 36 Cu. Ft. |
| Door | Two (2) swing solid doors, self-closing, one right hinged, one left hinged, magnetic door gasket |
| Shelves | Eight (8) adjustable shelves (adjustable in 1/2″ increments) |
| Mounting and installation | Swivel casters – locking front casters |
| Interior lighting | LED interior lights are safety shielded and switch controlled |
| Airflow management | Non-applicable |
| External probe access | 3/4″ probe access port on rear wall |
| Insulation | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Exterior materials | White powder coated steel |
| Access control | Keyed door lock |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Five (5) year compressor warranty |
| Product weight (lbs) | 345 |
| Shipping weight (lbs) | 395 |
| Exterior width (in) | 39.625″ |
| Exterior depth (in) | 34.75″ |
| Exterior height (in) | 81.75″ |
| Rated amperage | 3 Amps |
| Power plug/power cord | NEMA 5-15P plug, vaccine storage power cord warning label |
| Facility electrical requirement | 110 – 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency listing and certification | ETL, C-ETL listed: certified to UL471 standard. Meets or exceeds Energy Star v2.0 for Laboratory Refrigerators. Official listing may be found at www.energystar.gov |
Refrigeration System Temp Controller
| Maximum temperature variation (cabinet air) | +/-2.5° C |
| Stability (simulator ballast) | +/- 0.5° C |
| Adjustable temperature range | 36° F to 46° F (2° C to 8° C), Calibrated using a NIST traceable device, certificate included |
| Energy consumption (KWh/day) | <2.2 KWh/day *meets ENERGY STAR® v2.0 for Laboratory Refrigerators |
| Average heat rejection (BTU/hr) | <570 BTU/h |
| Noise pressure level (dBA) | 40 dBA or less installed |
| Pull down time to nominal operating temp | < 40 min (empty) |
| Compressor | Hermetic |
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) |
| Condenser | Tube and grid, high efficiency fan forced air |
| Evaporator | Fin and tube, high efficiency fan forced air |
| Defrost | Cycle Defrost |
| Performance note | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings |
Refrigeration SystemTemp Controller
| Controller technology | Microprocessor temperature controller |
| Battery backup | Non-applicable |
| Display technology | Non-applicable |
| Digital communication | Non-applicable |
| External alarm connection | Remote alarm contacts |
| Display probe | Product simulator bottle with glass bead media |
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm |
| Included accessories | Pharmacy refrigerator/freezer toolkit |
| Disclaimers | Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |